Gordon offers ceiling control joints for both acoustical and drywall ceilings at the perimeter as well as anywhere in the total ceiling area.
Ceiling drywall control joint detail.
Drywall ceilings never sounded so good.
Reclamation erosion control reclamation erosion control.
If the drywall joint is anywhere near the transition from the first to the second floor the seam will ridge out.
Joint sizes range from 2 to 4.
Control joints control joints are used to control stress caused by expansion and contraction across large ceiling expanses in drywall plasterboard systems.
Includes installation of corner beads trim and control joints.
An example of this is a stairway in a two story house.
Complete guide to proper joint treatment and surface preparation for drywall construction.
Ensemble acoustical drywall ceiling.
Addresses special environmental and lighting situations.
Gordon control joints complete the total perimeter concept.
Hand and mechanical finishing with setting type and drying type compounds.
Drywall or veneer plaster control joint clarkdietrich 093 zinc control joint is applied between abutting gypsum panels and is used to relieve stresses of expansion and contraction of drywall and veneer plaster systems in large ceiling and wall expanses over 30 in length.
Maximum distances are defined by the plasterboard manufacturers but generally recommended not to exceed 12m in any direction with perimeter relief.
These covers are suitable for most wall and ceiling finishes and are unobtrusive.
Joints and other construction details.
This article discusses expansion contraction of drywall gypsum board and the drywall control joint or expansion joint products used to prevent these problems in building interiors.
The gypsum association recommends installing control joints wherever partition walls or ceilings transverse construction joints.
Whether you need exterior design detail drawings or interior design detail drawings make the most informed decisions with our comprehensive ul assemblies directory and ul assembly details.
Between control joints does not exceed 2500 sq ft 230 m o section 20 3 4 ga 4 7 3 4 control joints in interior ceilings without perimeter relief shall be installed so that linear dimensions between control joints do not exceed 30 ft 9100 mm and total area between control joints does not exceed 900 sq ft 84 m.
All reclamation erosion control.
Joint sizes range from 1 to 10.
Usg offers professionals a complete set of architectural drawings for planning and estimation.
093 zinc control joint is typically installed from door header to ceiling from floor to ceiling in.
Assemblies directory design details.
Drywall control joints or gypsum board expansion joints are used to control cracking in gypsum board ceilings walls.
Notes location of control and expansion.
These dual gasket wall and ceiling covers are designed to allow for greater ranges of movement while maintaining a seamless look.